Pagina 1 - Packaged Series

GT-PG (50YE) Packaged SeriesSINGLE-STAGE HORIZONTAL, VERTICAL, AND DOWNFLOW PURON® SYSTEMS SIZES 018 - 070 [5.3 - 21.1 kW]Revised June 10, 2013

Pagina 2 - Table of Contents

GT-PG10GT-PG (50YE) SeriesBryant: Whatever it Takes.Air Flow Correction FactorsPSC Fan MotorAirfl ow Cooling Heating% ofRatedTotalCapacitySensibleCapac

Pagina 3

Bryant Geothermal Heat Pump SystemsGT-PG11Residential Products Technical GuideEntering Air Correction FactorsHeatingEnteringAir DB°FHeatingCapacityPow

Pagina 4 - GT-PG Design Features

GT-PG12GT-PG (50YE) SeriesBryant: Whatever it Takes.N/A N/A 1575 47.0 5.12 30.6 98 2.69 5.3N/A N/A 2100 48.3 4.68 32.5 91 3.02 4.522.3 - 1

Pagina 5

Bryant Geothermal Heat Pump SystemsGT-PG13Residential Products Technical GuidePerformance Data — GT-PG Model 018 - PSC Blower600 CFM Nominal (Rated) A

Pagina 6 - Unit Model Key

GT-PG14GT-PG (50YE) SeriesBryant: Whatever it Takes.Performance Data — GT-PG Model 018 - ECM BlowerOperation not recommendedOperation not recommended7

Pagina 7 - About AHRI/ISO/ASHRAE 13256-1

Bryant Geothermal Heat Pump SystemsGT-PG15Residential Products Technical GuidePerformance Data — GT-PG Model 024 - PSC Blower850 CFM Nominal (Rated) A

Pagina 8

GT-PG16GT-PG (50YE) SeriesBryant: Whatever it Takes.Performance Data — GT-PG Model 024 - ECM Blower850 CFM Nominal (Rated) Airfl ow Cooling, 950 CFM No

Pagina 9 - Piping End

Bryant Geothermal Heat Pump SystemsGT-PG17Residential Products Technical GuidePerformance Data — GT-PG Model 030 - PSC Blower950 CFM Nominal (Rated) A

Pagina 10 - Air Flow Correction Factors

GT-PG18GT-PG (50YE) SeriesBryant: Whatever it Takes.Performance Data — GT-PG Model 030 - ECM Blower1,000 CFM Nominal (Rated) Airfl ow Cooling, 1,100 CF

Pagina 11

Bryant Geothermal Heat Pump SystemsGT-PG19Residential Products Technical GuidePerformance Data — GT-PG Model 036 - PSC Blower1,250 CFM Nominal (Rated)

Pagina 12

GT-PG2GT-PG (50YE) SeriesBryant: Whatever it Takes.Table of ContentsWhat’s New With The GT-PG? ...3G

Pagina 13 - Operation not recommended

GT-PG20GT-PG (50YE) SeriesBryant: Whatever it Takes.Performance Data — GT-PG Model 036 - ECM Blower1,250 CFM Nominal (Rated) Airfl ow Cooling, 1,250 CF

Pagina 14

Bryant Geothermal Heat Pump SystemsGT-PG21Residential Products Technical GuidePerformance Data — GT-PG Model 042 - PSC Blower1,400 CFM Nominal (Rated)

Pagina 15

GT-PG22GT-PG (50YE) SeriesBryant: Whatever it Takes.Performance Data — GT-PG Model 042 - ECM Blower1,400 CFM Nominal (Rated) Airfl ow Cooling, 1,400 CF

Pagina 16

Bryant Geothermal Heat Pump SystemsGT-PG23Residential Products Technical GuidePerformance Data — GT-PG Model 048 - PSC Blower1,600 CFM Nominal (Rated)

Pagina 17

GT-PG24GT-PG (50YE) SeriesBryant: Whatever it Takes.Performance Data — GT-PG Model 048 - ECM Blower1,550 CFM Nominal (Rated) Airfl ow Cooling, 1,650 CF

Pagina 18

Bryant Geothermal Heat Pump SystemsGT-PG25Residential Products Technical GuidePerformance Data — GT-PG Model 060 - PSC Blower1,950 CFM Nominal (Rated)

Pagina 19

GT-PG26GT-PG (50YE) SeriesBryant: Whatever it Takes.Performance Data — GT-PG Model 060 - ECM Blower1,825 CFM Nominal (Rated) Airfl ow Cooling, 2,050 CF

Pagina 20

Bryant Geothermal Heat Pump SystemsGT-PG27Residential Products Technical GuidePerformance Data — GT-PG Model 070 - ECM Blower1,950 CFM Nominal (Rated)

Pagina 21

GT-PG28GT-PG (50YE) SeriesBryant: Whatever it Takes.Physical DataModel 018 024 030 036 042 048 060 070Compressor (1 Each) Copeland ScrollFactory Charg

Pagina 22

Bryant Geothermal Heat Pump SystemsGT-PG29Residential Products Technical GuideDimensions — Vertical Upfl ow GT-PG (50YE) SeriesCondensate is 3/4” PVC f

Pagina 23

Bryant Geothermal Heat Pump SystemsGT-PG3Residential Products Technical GuideCopeland – turned theory into practical reality, using sophisticated, com

Pagina 24

GT-PG30GT-PG (50YE) SeriesBryant: Whatever it Takes.Dimensions — Vertical Upfl ow GT-PG (50YE) SeriesVerticalUpfl owModelDischarge ConnectionDuct Flange

Pagina 25

Bryant Geothermal Heat Pump SystemsGT-PG31Residential Products Technical GuideDimensions — Vertical Downfl ow GT-PG (50YE) Series Condensate is 3/4” PV

Pagina 26

GT-PG32GT-PG (50YE) SeriesBryant: Whatever it Takes.Dimensions — Vertical Downfl ow GT-PG (50YE) Series VerticalDownfl owModelDischarge ConnectionDuct F

Pagina 27

Bryant Geothermal Heat Pump SystemsGT-PG33Residential Products Technical GuideDimensions — Horizontal GT-PG (50YE) Series Condensate is 3/4” FPT.Unit

Pagina 28 - Physical Data

GT-PG34GT-PG (50YE) SeriesBryant: Whatever it Takes.Dimensions — Horizontal GT-PG (50YE) Series HorizontalModel1Discharge ConnectionDuct Flange Instal

Pagina 29

Bryant Geothermal Heat Pump SystemsGT-PG35Residential Products Technical GuideElectrical DataRated Voltage of 208-230/60/1 Min/Max Voltage of 1

Pagina 30

GT-PG36GT-PG (50YE) SeriesBryant: Whatever it Takes.GT-PG ECM Electrical Wiring Diagram - 96B0005N37

Pagina 31

Bryant Geothermal Heat Pump SystemsGT-PG37Residential Products Technical GuideGT-PG PSC Electrical Wiring Diagram - 96B0005N36

Pagina 32

GT-PG38GT-PG (50YE) SeriesBryant: Whatever it Takes.GT-PG ECM & Whole House Dehumidifi cation Electrical Wiring Diagram - 96B0216N33

Pagina 33 - Condensate is 3/4” FPT

Bryant Geothermal Heat Pump SystemsGT-PG39Residential Products Technical GuideGT-PG ECM Control FeaturesThe ECM fan is controlled by an interface boar

Pagina 34 - Bryant: Whatever it Takes

GT-PG4GT-PG (50YE) SeriesBryant: Whatever it Takes.The GT-PG Series has abundant features and industry leading effi ciency.Application Flexibility• Ei

Pagina 35 - Electrical Data

GT-PG40GT-PG (50YE) SeriesBryant: Whatever it Takes.GT-PG ECM Control FeaturesECM Board Tap SettingsYGGGGRWOY2Y1GRCY2Y1GOWCRDHAL1AAAL1SW1SW2SW3SW4SW5S

Pagina 36

Bryant Geothermal Heat Pump SystemsGT-PG41Residential Products Technical GuideAirfl ow in CFM with wet coil and clean air fi lterECM Blower Performance

Pagina 37

GT-PG42GT-PG (50YE) SeriesBryant: Whatever it Takes.PSC Blower Performance DataAirfl ow in CFM with wet coil and clean air fi lterModelFanSpeedRatedAirfl

Pagina 38

Bryant Geothermal Heat Pump SystemsGT-PG43Residential Products Technical GuideAuxiliary Heat Electrical DataAuxiliary Electric HeatAuxiliary Heat Rati

Pagina 39 - GT-PG ECM Control Features

GT-PG44GT-PG (50YE) SeriesBryant: Whatever it Takes.The water-to-re frig er ant heat exchanger and refrigerantsuction lines shall be insulated to prev

Pagina 40 - LED's

Bryant Geothermal Heat Pump SystemsGT-PG45Residential Products Technical GuideWarranty InformationThe 2010 standard warranty applies to units ordered

Pagina 41 - ECM Blower Performance Data

GT-PG46GT-PG (50YE) SeriesBryant: Whatever it Takes.Notes

Pagina 42 - PSC Blower Performance Data

Bryant Geothermal Heat Pump SystemsGT-PG47Residential Products Technical GuideNotes

Pagina 43 - Auxiliary Heat Ratings

GT-PG48GT-PG (50YE) SeriesBryant: Whatever it Takes.Date Page # Description10 June, 13 38 Updated Unit Wiring Diagram8 May, 13 All Pages Re-numbered4

Pagina 44

Bryant Geothermal Heat Pump SystemsGT-PG5Residential Products Technical GuideOptions & Accessories• Optional hot water generator with internally

Pagina 45 - Accessories & Warranty

GT-PG6GT-PG (50YE) SeriesBryant: Whatever it Takes.Unit Model Key5 0 J0 2 4 BC 3 1 14 5 6 789101112PrefixSeries018, 024, 030, 036, 042, 048, 060,

Pagina 46

Bryant Geothermal Heat Pump SystemsGT-PG7Residential Products Technical GuideAbout AHRI/ISO/ASHRAE 13256-1About AHRI/ISO/ASHRAE 13256-1AHRI/ASHRAE/ISO

Pagina 47

GT-PG8GT-PG (50YE) SeriesBryant: Whatever it Takes.AHRI/ISO/ASHRAE/ANSI 13256-1 PerformanceASHRAE/AHRI/ISO 13256-1. English (I-P) UnitsASHRAE/AHRI/ISO

Pagina 48 - Revision History

Bryant Geothermal Heat Pump SystemsGT-PG9Residential Products Technical GuideRef er ence Calculations & LegendLWT = EWT -HEGPM x 500LAT = EAT +HCC