Bryant TSTATBBN2S01-C Manuale di Installazione

Navigare online o scaricare Manuale di Installazione per Termostati Bryant TSTATBBN2S01-C. Bryant TSTATBBN2S01-C Unit installation Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
TABLE OF CONTENTS
Electrical Data 13
Blower Speed Selection 14
Blower Performance Table 16
Electrical - Low Voltage 16
Freeze Protection Selection 16
Water Valve Wiring 17
Electrical Wiring Schematic 17
Thermostat Wiring 18
CXM Control Description 19
Troubleshooting Information 22
Troubleshooting Analysis 23
Major Replacement Components 26
Unit Start-Up Procedure 26
Operating Limits 26
Operating Pressures 28
Pressure Drop Table 28
Warranty 31
Model Nomenclature 2
Storage 2
Physical Data 3
Pre-Installation 3
Physical Dimensions 4
Unit Installation 5
Duct System 5
Water Connections 6
Condensate Drain 6
Ground Loop Application 7
Flushing 7
Antifreeze 8
Open Loop/Well Water Installation 9
Water Quality Standards 10
Hybrid Loop/Well Applications 10
Hot Water Generator 11
Electrical - Line Voltage 13
INSTALLED BY:
50YBV
Ultra High Ef ciency
Vertical Two-Stage
Geothermal System
Installation, Operation &
Maintenance Instructions
Revision: 07/21/05D
GT-X
Vedere la pagina 0
1 2 3 4 5 6 ... 31 32

Sommario

Pagina 1 - TABLE OF CONTENTS

TABLE OF CONTENTSElectrical Data 13Blower Speed Selection 14Blower Performance Table 16Electrical - Low Voltage 16Freeze Protection Selection 16W

Pagina 2 - Model Nomenclature

Page 10HYBRID GROUND LOOP/WELL WATER SYSTEMSThe GT-X dual refrigerant circuits with individual water connections for each, allows each refrigerant cir

Pagina 3 - Pre-Installation

Page 11Shut-off Valve with WasteVent at high pointCold InletHot Outletto homeInsulated water lines -5/8” OD 50 ft maximumPoweredWaterHeaterUpperelemen

Pagina 4 - INSTALLATION

Page 12Water Tank Preparation1. Turn off power or fuel supply to the hot water tank.2. Connect a hose to the drain valve on the water tank.3. Shut

Pagina 5

Page 13ELECTRICAL-LINE VOLTAGEAll fi eld installed wiring, including electrical ground, must comply with the National Electrical Code as well as all ap

Pagina 6 - Condensate Drain

Page 14ECM FAN MOTORCFM Adjust settings: The CFM adjust setting allows four selections. The NORM setting is the factory default position. The + or – s

Pagina 7 - GROUND LOOP APPLICATION

Page 15Cooling settings: 50YB,YC,YD,YE units* Heating settings: 50YD, YE units* Aux/Emerg Heat settings: 50YB,YC,YD,YEVersion I Version I Version I

Pagina 8 - Freeze Protection Setting

Page 16Figure 19. Low Voltage Field WiringThermostat ConnectionsThe thermostat should be wired directly to the ICM2 control board as shown in Figure 1

Pagina 9 - Flow Regulation

Page 17Accessory ConnectionsA terminal paralleling the compressor contactor coil have been provided on the CXM/DXM control of the GT-X line. "A&q

Pagina 10

Page 18Electrical Schematic

Pagina 11 - HOT WATER GENERATOR

Page 19Features • Anti-short cycle protection • High and Low pressure cutouts • Water Coil freeze protection • Air Coil freeze protection • Rando

Pagina 12 - Initial Start-Up

Page 2GENERAL INFORMATIONStorageCAUTION: DO NOT store or install units in corrosive environments or in locations subject to temperature or humidity ex

Pagina 13 - ELECTRICAL-LINE VOLTAGE

Page 20Safety FeaturesThe following safety features are provided to protect the compressor, heat exchangers, wiring and other components from damage c

Pagina 14 - ECM FAN MOTOR

Page 21Diagnostic FeaturesThe Status LED on the CXM control advises the serviceman of the current status of the CXM control. The status LED can displa

Pagina 15

Page 22Troubleshooting InformationGeneralCXM board troubleshooting in general is best summarized as simply varifying inputs and outputs. After this p

Pagina 16 - Rev.: 07/06/05D

Page 23See “Does not Operate in Clg”See “Only Comp Runs”StartDid Unit Attempt to Start?Did Unit Lockout at Start-up?Unit Short Cycles?Only Fan Runs?On

Pagina 17 - Water Solenoid Valves

Page 24Functional TroubleshootingFault Htg Clg Possible Cause SolutionMain power Problems X X Green Status LED Off Check Line Voltage circuit breaker

Pagina 18 - Electrical Schematic

Page 25Functional Troubleshooting (cont.)Performance TroubleshootingOnly Compressor Runs X X Thermostat wiringCheck G wiring at heat pump. Jumper G a

Pagina 19 - CXM Control Description

Page 26Operating LimitsEnvironment – This unit is designed for indoor installation ONLY.Power Supply – A voltage variation of +/– 10% of nameplate uti

Pagina 20 - Safety Features

Page 27Start up ProcedureWhen the disconnect switch is closed, high voltage is present in some areas of the electrical panel. Exercise caution when wo

Pagina 21 - ICM2 Control Board

Page 28Table 13. Unit operating pressures and temperaturesTable 11. Water Temperature Change Through Heat ExchangerTable 12. Water Pressure Drop Tab

Pagina 23 - Troubleshooting Chart

Page 3To avoid equipment damage, DO NOT use these units as a source of heating or cooling during the construction process. The mechanical components a

Pagina 25 - Performance Troubleshooting

Page 31CARRIER CORPORATIONLIMITED EXPRESS WARRANTY/LIMITATION OF REMEDIES AND LIABILITY FORRESIDENTIAL GEOTHERMAL PRODUCTSIt is expressly understood t

Pagina 26 - UNIT START UP

© LSB 2000 Rev.: 7/21/05D*69197346*69197346T0IAANSRDARD33PSMUPHEATTEAWRRCEUOSHTWIITOARIASCOMPLYNGMRERUTCAFUNACERTIFIEDThe manufacturer works contin

Pagina 27 - CXM Board

Page 4Physical DimensionsINSTALLATIONOverall Cabinet Discharge ConnectionWater Connections Electrical KnockoutsReturn Connectionusing std deluxe filte

Pagina 28 - Rev.: 1/30/01M

Page 5The installation of geothermal heat pump units and all associated components, parts and accessories which make up the installation shall be in a

Pagina 29

Page 6Never use fl exible hoses smaller than 1" inside diameter on the unit and limit hose length to 10 ft. per connection. Check carefully for wa

Pagina 30

Page 7 Type Minimum Temperature for Freeze Protection 10°F 15°F 20°F 25°F Methanol 25% 21% 16% 10%100% USP food grade Propylene Gl

Pagina 31 - CARRIER CORPORATION

Page 8Antifreeze may be added before, during or after the fl ushing procedure. However, depending upon which time is chosen, antifreeze could be wasted

Pagina 32 - *69197346*

Page 9Water QualityWater quality should be plentiful and of good quality. Table 4 shows recommended water quality guidelines. The unit can be ordered

Commenti su questo manuale

Nessun commento