DESCRIPTION
These duct-free split systems cool, heat (heat pump systems
only) dehumidify, circulate, and filter the air with minimum
maintenance. They are the ideal complement to your ducted
system when it is impractical or prohibitively expensive to use a
ducted system. The outdoor units, when matched with model
619E fan coil units, offer many technological features and reli-
able operation.
The duct-free split systems are perfect for add-ons, such as an
office or family room addition, and whenever you have special
space requirements; like for a computer room. Or consider duct-
free split systems when changes in the cooling load cannot be
handled by the existing system; for instance, when adding heat-
generating equipment to an already air-conditioned space.
Split systems can also be used when adding air conditioning to
spaces that are heated by hydronic or electric heat, and no
ductwork exists. Historical renovations are another application
for which duct-free split systems are well suited, especially
when preserving the looks of the original structure is essential.
When noise is a concern, these whisper-quiet split systems are
your answer because you don’t have to worry about duct
design.
If security is an issue, outdoor and indoor units are connected
only by refrigerant piping to prevent intruders from crawling
through ductwork. Also, since the outdoor units can be installed
6-in. away from outside walls, coils are protected from vandals
and severe weather.
In addition, the compact duct-free split systems take only a few
hours to installl, without any major interruptions to the custom-
ers’ workplace or home.
STANDARD SYSTEM FEATURES
HIGH-EFFICIENCY design with SEERs (Seasonal Energy Effi-
ciency Ratios) up to 12.0 and HSPFs (heating seasonal perfor-
mance factors; heat pump systems only) of 6.8.
MICROPROCESSOR CONTROL for accurate control of the de-
sired comfort level.
EXTENSIVE DIAGNOSTICS alert the user to the existence of
problems.
BUILT-IN RELIABILITY COMPONENTS include a suction-line
accumulator that safeguards the compressor against loss of lu-
brication, while start capacitors and relays (non-scroll units) as-
sure dependable start-ups, especially during low-voltage
conditions (down to 187 v). High- and low-pressure safety
switches, crankcase heater (non-scroll units), liquid line filter
drier (538A, 538C, 538S), bi-flow liquid line filter drier (538D),
and lock-out protection are also standard on most sizes.
538A
538S (048 Shown)
619E
538C/D009,012
Bryant
Day &Night
Payne
Air Conditioning
HIGH WALL DUCT-FREE,
SPLIT SYSTEMS
Model 619E
Sizes 009-024
3
4
to 2 Tons
Form No. PDS 619E.09.1
PRELIMINARY PRODUCT DATA
Vedere la pagina 0
1 2 3 4 5 6 ... 31 32

Sommario

Pagina 1 - PRELIMINARY PRODUCT DATA

DESCRIPTIONThese duct-free split systems cool, heat (heat pump systemsonly) dehumidify, circulate, and filter the air — with minimummaintenance. They a

Pagina 2 - CONTENTS

DIMENSIONAL DRAWING — BASE UNIT — 538A018-024 CONDENSING UNITSUNIT538AAB CDEFGHft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm f

Pagina 3

DIMENSIONAL DRAWING, BASE UNIT — 538D018,024 HEAT PUMP UNITSUNIT538DAB CDEFft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm018 2-11⁄8638.2

Pagina 4 - MODEL DESCRIPTION

DIMENSIONAL DRAWING, BASE UNIT — 538S CONDENSING UNITSUNIT538SABCDEFGHFt-in. mm Ft-in. mm Ft-in. mm Ft-in. mm Ft-in. mm Ft-in. mm Ft-in. mm Ft-in. mm0

Pagina 5 - SYSTEM CAPACITIES

DIMENSIONAL DRAWING, BASE UNIT — 619E009,012 FAN COIL UNITSUNIT619EWEIGHT A B CLb Kg in. mm in. mm in. mm009 18.7 8.5 33.46 850 11.02 280 6.29 160012

Pagina 6

DIMENSIONAL DRAWING, BASE UNIT — 619E018,024 FAN COIL UNITSUNIT619EWEIGHT018 39 Lb [17.5 Kg]024 43 Lb [19.5 Kg]NOTES:1. Dimensions in [ ] are in milli

Pagina 7

ELECTRICAL DATACONDENSING UNITSUNITVOLTAGE(Single Ph, 60 Hz)OPERATINGVOLTAGEMINIMUM*OPERATINGVOLTAGEMAXIMUM*COMPRLAFANFLAPOWERMCA† MOCP†538A 018208/23

Pagina 8

ELECTRICAL DATA (cont)FAN COIL UNITSINDOORUNIT619EV (Single-Ph, 60 Hz)OPERATING VOLTAGE* FANMinimum Maximum FLA009† 115 104 127 —012† 208/230 187 253

Pagina 9

TYPICAL INSTALLATION — HIGH-WALL SYSTEMS, 9,000 AND 12,000 BTUH(Cooling-Only System Shown)LEGENDNEC — National Electrical Code*Standard.†Field supplie

Pagina 10

TYPICAL INSTALLATION — HIGH-WALL SYSTEMS, 18,000 AND 24,000 BTUH(Cooling Only System Shown)LEGENDNEC — National Electrical CodePipingLine Voltage24 VT

Pagina 11

APPLICATION DATA1. Unit selectionSelect equipment to either match or be slightly less than an-ticipated peak load. This provides better humidity contr

Pagina 12

The indoor units include protection against freeze-up (heatpumps), high discharge temperature, and self diagnostics to en-sure reliability.RESTART FUN

Pagina 13

APPLICATION DATA (cont)9. Metering devicesa. 009, 012 units — The 009 and 012 units have capillarytubes for refrigerant metering located in the outdoo

Pagina 14

APPLICATION DATA (cont)3) For line lengths over 50 ft (018,024 only):a) A crankcase heater should be added to scrollcompressor units (all non-scroll c

Pagina 15 - MULTI-SPLIT CONDENSING UNITS

APPLICATION DATA (cont)e) Changes in piston size — The metering device for along-line application must be adjusted to compen-sate for the frictional l

Pagina 16 - FAN COIL UNITS

APPLICATION DATA (cont)j) Elevated configuration — Indoor unit installed abovethe outdoor unit (see figure at right):• If there is over 25 ft of lift, a

Pagina 17 - (Cooling-Only System Shown)

TYPICAL WIRING SCHEMATIC — 538C009,012 COOLING ONLY SYSTEM (012 Shown)RELAY CHARTCompressor K1(See Legend and Notes, page 28.)24

Pagina 18 - (Cooling Only System Shown)

TYPICAL WIRING SCHEMATIC — 538A018,024 COOLING-ONLY SYSTEMRELAY CHARTCompressor K13THERMISTOR EQUIVALENCETemperature Resistance°F °C V95 35 6,50072 22

Pagina 19 - OUTDOOR UNITS

TYPICAL WIRING SCHEMATIC, 538D009,012 HEAT PUMP SYSTEM (012 Shown)RELAY CHARTCompressor K1Outdoor Fan K2Rev. Valve K3(See Legend and Notes, page 28.)2

Pagina 20 - MAXIMUM LINE LENGTHS

TYPICAL WIRING SCHEMATIC — 538D018,024 HEAT PUMP SYSTEMTHERMISTOR EQUIVALENCETemperature Resistance°F °C V95 35 6,50072 22 11,40032 0 32,500All thermi

Pagina 21

LEGEND AND NOTES FOR TYPICAL WIRING SCHEMATICSOPERATING SEQUENCE619E CONTROL SYSTEM — The 619E unit is equipped with amicroprocessor control which ope

Pagina 22

OPERATING SEQUENCE (cont)• Maximum Dehumidification Mode — When the dehumidifica-tion mode is selected, the indoor fan will operate continuouslyat the s

Pagina 23 - CONDENSING UNIT SOUND RATINGS

STANDARD FEATURES AND FIELD-INSTALLED ACCESSORIESSTANDARD FEATURE/FIELD-INSTALLEDACCESSORYHIGH WALLSYSTEMS(619B,D)Internal Condensate Pump AMounting B

Pagina 24 - Compressor K1

*Minimum unit run time starts when outdoor coil temperature drops below 34 F, then accumulates runtime regardless of coil temperature.Electronic Contr

Pagina 25

ENGINEER’S SPECIFICATION GUIDE — OUTDOOR UNITS (Models 538A, 538C, 538D, and 538S )GENERAL: Furnish and install a Model 538A, 538C, 538D, or538S air-t

Pagina 26 - Rev. Valve K3

ENGINEER’S SPECIFICATION GUIDE — HIGH WALL FAN COIL UNITS (Model 619E)GENERAL: Furnish and install indoor, wall-mounted, draw-thru,direct expansion, i

Pagina 27

MODEL DESCRIPTIONOUTDOOR UNITSFAN COIL UNITS*009 systems only.†538C,D only.**538A, 538D only.††538A, 538D, 538S only.\538S only.*009 systems ony.4

Pagina 28 - OPERATING SEQUENCE

SYSTEM CAPACITIESSYSTEMTYPENOMINALSYSTEMCAPACITY(Tons)FAN COILTYPE(S)INDOOR SECTIONSOUTDOORSECTION538TOTALSTANDARDCFM (ATHIGHSPEED)SYSTEMNETCOOLING(Bt

Pagina 29 - OPERATING SEQUENCE (cont)

SPECIFICATIONS — 538A AND 538C CONDENSING UNITSUNIT 538C 009 538C 012 538A 018 538A 024NOMINAL CAPACITY (Tons)3⁄4111⁄22OPERATING WEIGHT (lb) 55.0 62.0

Pagina 30

SPECIFICATIONS — 538D HEAT PUMP UNITSUNIT 538D 009 012 018 024NOMINAL CAPACITY (Tons)3⁄4111⁄22OPERATING WEIGHT (lb) 60.7 66.6 154 167REFRIGERANT TYPE

Pagina 31

SPECIFICATIONS — 538S CONDENSING UNITSUNIT 538S 024 048NOMINAL CAPACITY (Tons) 24OPERATING WEIGHT (lb) 159 292REFRIGERANT TYPE R-22Control (Cooling) T

Pagina 32 - Day & Night

DIMENSIONAL DRAWING, BASE UNIT — 538C/D009,012 COOLING ONLY AND HEAT PUMP UNITSNOTES:1. Dimensions in [ ] are in millimeters.2. Direction of airflow.3.