Bryant PREFERREDT A07045 Manuale Utente Pagina 23

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 22
23
A07221
Fig. 15 -- Reattach Display Module
9. Turn on power to equipment. On power up, all display segments will
light for 5 sec. For the next 5 sec a 2-- digit code appears on large display
which identifies Thermidistat Control configuration. Refer to Option 33.
a. AC 1-- stage air conditioner
b. HP 1--stage heat pump
c. A2 2 -- stage air conditioner
d. H2 2--stage heat pump
e. hh Hybrid Heat system with 1 -- stage heat pump
f. h2 Hybrid Heat system with 2 -- stage heat pump
g. H heating only system
h. C cooling only system
Vedere la pagina 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 79 80

Commenti su questo manuale

Nessun commento